A Top Safety and Protection Solution Worldwide!
Page 15 of 32 Ver 1.0
1) The Nodes Type NC,NO,EOL should reference the wired input sensor type.
The Default is NC and all the inputs are shorted with wires. If you want to
contact the wired sensors, then please replace the short wires by wired
sensors directly. Please remain the no-use input in short-circuit with wires.
Please see 8.4 Install the Wired Sensors and Electricity equipments
2) Zones’ Attribute definition of the wired zone is the same as the wireless zone.
3) The unit can accept total 8 wired sensors to 8 wired zones; each zone can be
assigned one wired sensor, and renamed by SMS Command.
4) Wired Zone Serial Number, Default Zone Name and Zone Attributes Table.
Intrusion from Left Fence
Intrusion from Right Fence
Intrusion from Front Fence
Intrusion from Garden Fence
24-Hour zones, This attribute can not
be modified. In arm or disarm or stay
mode, once the sensor in these zones
triggered, will alarm immediately.
SOS zone, The attribute can not be
modified. In arm or disarm or stay
mode, once the sensor in these zones
triggered, will alarm immediately, but
not drive the siren.
6.2.2.3 Basic Setting